DORMATIC ALUMINIUM SHUTTER SYSTEMS

1-Passing the roller shutter pallets to each other through special channels on them
by installing plugs on both sides of the pallet group formed by
After fixed, it is attached to the pipe with steel hangers and mounted on the wall.
With the movement of the panel in the ducted strut profiles, the panel is wound on the pipe and opened
the system from which it shuts down . Small gauge systems shutters, large gauge systems shutters
Called. 

2-Shutter pallets should be manufactured by rollforming method

3- Shutter polyurethane filled pallets in accordance with ISO 3582 norm against fire
there should be special polyurethane filler that shows durability.
4-Polyurethane filler does not contain CFC, against mold, insects and bacteria
must have protection feature .
5-SP80 and ROLL-PLUS to high-quality polyurethane, refined with polyamide
Paint system that resists burnt friction should be used.
6- Top face coating of pallets, formed polyamide system, bottom paint + transparent
It should be semi-matte with a thickness of 30μm so that it is a coating.
7-Bottom (inner) face coating of pallets, translucent polyester, available polyurethane varieties i
and should be 4μm thick with adhesion to adhesives.
8-Material alloy values must comply with EN 573 -3, TS 138 EN 10001.
9-Mechanical properties must comply with EN 1396.
10-Dimensional tolerances must comply with EN 485 - 4.
11- System size for the installation of the panel created from the roller shutter pallets to the pipe
Use steel hanger of suitable thickness and length, which can also be installed with slit or screw
The range should not be wider than 50 cm.
12- System manufacturer box and side cover up to 39 c m winding diameter and 6 m width
be able to give, make special applications in larger sizes .
 SL-39, SL-41, SL- 45 pallets with 21 mm depth, 53.2 mm width and 1.1 mm meat
A struted U profile should be used in thickness.
SL-55, SL-56, with pallets 27.7 mm depth , 75 mm width and 1.4 mm meat
A struted U profile should be used on the pediment of k.
SL-75, SL-77 pallets with 35 mm depth, 90 mm width and 1.8 mm wall thickness
A strut U profile should be used.
13- The steel parts of the system must be galvanized.
14- Tightly with plastic plug stapler suitable for each pallet for mounting pallets to each other
must be fixed.

15- Optional deadbolt, locked deadbolt, block lock systems should be applied to the system. (if without motor)
16- Easy movement in strut without rubbing against the strut U profiles of the roller shutter pallets
A strut U head or a strut U reel should be used.
17- The lower part (skirt profile) suitable for the dimensions of the shutter pallets is at least 1.1 mm meat
should be thick .
18- The system manufacturer shall select optional mechanism options; automatic roller manual,
manual, motor mechanism with gearbox, geared motor mechanism
should be able to offer .
19- The manufacturer of roller shutters for motorized mechanisms should be questioned with a separate specification.

20-On the strut inner sidewalls, it will reduce the friction and sound of the system and the panel surface
There should be a bristle wick that will prevent the scum between the struts and the perpendicular.
21- Sealing to the panel of the lower part profile of the panel between the panel of the spiral system and the floor
The provider should be fitted with rubber pipe wicks.

DORMATIC FIRE GATE
Fire doors; preventing the smoke-flame passage during the fire and the spread of the fire between the sections,
doors certified to allow evacuation and maintain their durability within the specified strength period
Must be.
1.QUALITY AND CERTIFICATION;
1.1. The provider must have an ISO 9001 quality assurance certificate.
1.2. The provider must have a TSE Service location qualification certificate.
1.3. The provider company must have an after-sales qualification certificate from the Ministry of Industry of the Republic of Turkey.
1.4. The provider must be a member of IDA (International Door Association).
1.5. The provider must have 18001 OHSAS (Occupational Health and Safety Management System) certificate.
2.PRODUCT SPECIFICATIONS;
2.1. Doors must be fire resistant of class EI 45, EI 60, EI 90, E 120.
2.2. The door frame must be made of 2.0 mm DKP or galvanized steel and must be of a structure that prevents air flow.
2.3. The door leaf should be produced from 1,2 mm DKP or galvanized sheet with sandwich panel technique.
2.4. Rock wool should be used as insulation material.
2.5. The door frame and leaf must be painted in the desired RAL color.
2.6. There should be 12mm thick fire-resistant drywall.
2.7. There should be a smoke-proof fire gasket on the door frame by expanding in dimensions of 2*20mm.
2.8. The sash thickness of the fire-resistant door for 60 minutes should be 60 mm.
2.9. The sash weight of the door resistant to fire for 60 minutes should be approximately 26 kg/m2.
2.10. 90-120 minutes fire resistant door should have a sash thickness of 70 mm.
2.11. The sash weight of the fire resistant door for 90-120 minutes should be approximately 28 kg/m2.
2.12. Doors should have 2 hinges on each wing, one of the DIN certified hinges is self-closing.
Provides
 It should be a spring hinge and the other should be a ball hinge that can be adjusted vertically.
2.13. For doors with a height above 2400 mm, the number of hinges should increase to 3 pieces.
2.14. The door is ergonomically designed, black color, mounted on the sash with fire resistant door handles
must be available with a lock and a cylindrical key.
2.15. Doors must have TS EN 1634-1 Certificates.
2.16. There should be a 1.5mm thick anchor sheet on the door frame that allows wall mounting.
2.17. Certified panic bars must be added to escape doors.
2.18. In the use of panic bars, even if the door is locked from the outside, it must be able to be opened from the inside with a panic arm.
2.19. The panic bars used must be UNE-EN 1125 certified and the door must be opened with a force of less than 80 N.
should provide.2.20. There shall be operating instructions necessary for installation and maintenance.
2.21. Doors must provide heat and sound insulation.
2.22. Double-leaf doors must have a closing sequencer as standard